Commercial 10 HP, 3-Phase-230V (Includes Control Box, DC2600, DC1603 & DRV330) 12-15 users sanding fine dust

$17,895.00

The 10hp power pump can be used with the DC2600 for vacuuming up fine dust in an auto body shop.  This dirt can not be used for general cleaning.  Multiple users can use the vacuum at the same time.  The CR1526 comes with a primary and secondary filter.  The DC2600 is the primary filter and the DC1603 is the secondary filter.  For more information about obtaining a commercial central vacuum system please email us at lindsay@fullnet.net.   We assist in planning and designing these systems.

Please call to purchase 1-800-221-1862. Technical assistance and planning support provided.

Brand: VacuMaid

Out of stock

SKU: CR1526A Categories: ,

CR-1526C is 208 Voltage, CR-1526A is 230 Voltage, CR-1526B is 460 Voltage

60 Hz. 50 Hz.
Induction Motor: ……………………………………… 3Ph, 10HP, 3450 RPM 3 Ph, 8HP, 2850 RPM
Voltage: ………………………………………………….. 208, 230, 460 190-220/380-415  (customer must specify voltage)
Amperage (Approx.): ……………………………………………………….. 30, 26, 15 17.4-17.2/8.7-8.6
*Electrical Service to Unit: …………………………………. No. 8, No. 10, No. 14 No. 14
Pump: …………………………………………………… Regenerative
Airflow @ 3″ Opening (Approx.): ……………………………………….. 405 C.F.M. 9.5 CMM
Sealed Vacuum (Approx.): ………………………………………………….. 125″ H2O 292 cm H2O

RECOMMENDED RELIEF VALVE SETTING: ……………………. **90″ H2O **188 cm H2O

Dimensions (Approx.):
Power Unit:
Length: …………………………………………………. 24-1/8″
Width: ………………………………………………….. 18-5/8″
Height: ……………………………………………… 21-13/16″
Shipping Weight (Approx.): …………………………………………………… 300 lbs.
Inlet Connection: ……………………………………………………….. 3-1/2″ I.D.
Outlet Connection: ……………………………………………………….. 3-1/2″ I.D.

Primary Filter – DC-2600 (For use with fine dust ONLY.)
Filtration: …………………… Five stage cyclonic with gate valve.
Inlet and Outlet Connections: …………………………………………… 3-1/2″ O.D.
Diameter: …………………………………………………………………. 25″
Height: …………………………………………………………………. 87″
Radius (including support legs): …………………………………………………… 17″
Capacity (Approx.): ……………………………………………………………. 15 Gal.
Shipping Weight (Approx.): …………………………………………………… 265 lbs.

Secondary Filter – DC-1603
Filtration: ………………………. High efficiency reusable bag filter.
Inlet and Outlet Connections: …………………………………………… 3-1/2″ O.D.
Diameter: …………………………………………………………………. 19″
Height: …………………………………………………………………. 29″
Filter Area (Approx.): ……………………………………………………….. 7.5 Sq. Ft.
Shipping Weight (Approx.): …………………………………………………….. 60 lbs.
Replacement Filter: ………………………………………………………….. FB-1603

*Electrical Service to unit should be installed by a licensed electrician.
*Preferred Setting

NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001).

**NOTE: Relief Valve should be set at a preferred setting of 90″ H2O at 60 Hz. and 188 cm H2O at 50 Hz., when possible, use the preferred/recommended settings above.

NOTE: You should contact the factory for applications before ordering.

NOTE: First five feet of exhaust MUST be metal 3-½” O.D. tubing (SF-3075).